您的当前位置:首页正文

PF-04957325_NP-HPLC_23381_MedChemExpress

2022-02-06 来源:好走旅游网
Data File D:\\CHEM\\DATA\\20161205\\20161205 2016-12-05 15-57-19\\019-0401.DSample Name: DK3788-036-1_RS=====================================================================Acq. Operator : CWQ_497 Seq. Line : 4Acq. Instrument : HPLC-10 Location : Vial 19Injection Date : 2016-12-05 17:02:59 Inj : 1 Inj Volume : 5.000 µlDifferent Inj Volume from Sequence ! Actual Inj Volume : 2.000 µlAcq. Method : D:\\CHEM\\DATA\\20161205\\20161205 2016-12-05 15-57-19\\OZ,85B-ETOH,210NM,C2.MLast changed : 2016-12-05 16:04:27 by CWQ_497 (modified after loading)Analysis Method : D:\\CHEM\\.M\\HY-308_71-H01EE02,210NM,C1.M Last changed : 2016-12-06 08:56:57 by CWQ_497 (modified after loading)Catalog No : HY-15426 Batch#23381 C-NP-21 Additional Info : Peak(s) manually integrated VWD1 A, Wavelength=210 nm (20161205\\20161205 2016-12-05 15-57-19\\019-0401.D) 6.811 7.585mAU2001000-100-200-300-40002.557.51012.51517.5min ===================================================================== Area Percent Report ===================================================================== Sorted By : SignalMultiplier: : 1.0000Dilution: : 1.0000Use Multiplier & Dilution Factor with ISTDs Signal 1: VWD1 A, Wavelength=210 nm Peak RetTime Type Width Area Height Area # [min] [min] [mAU*s] [mAU] %----|-------|----|-------|----------|----------|--------| 1 6.811 MM 0.2144 3313.58643 257.57053 49.1535 2 7.585 MM 0.2334 3427.71802 244.75974 50.8465 Totals : 6741.30444 502.33026 ===================================================================== *** End of Report ***HPLC-10 2016-12-06 08:57:02 CWQ_497Page 1 of 1

Data File D:\\CHEM\\DATA\\20161205\\20161205 2016-12-05 15-57-19\\005-0301.DSample Name: DK3788-036-1=====================================================================Acq. Operator : CWQ_497 Seq. Line : 3Acq. Instrument : HPLC-10 Location : Vial 5Injection Date : 2016-12-05 16:41:29 Inj : 1 Inj Volume : 5.000 µlDifferent Inj Volume from Sequence ! Actual Inj Volume : 2.000 µlAcq. Method : D:\\CHEM\\DATA\\20161205\\20161205 2016-12-05 15-57-19\\OZ,85B-ETOH,210NM,C2.MLast changed : 2016-12-05 16:04:27 by CWQ_497 (modified after loading)Analysis Method : D:\\CHEM\\.M\\HY-308_71-H01EE02,210NM,C1.M Last changed : 2016-12-06 08:56:57 by CWQ_497 (modified after loading)Catalog No : HY-15426 Batch#23381 C-NP-21 Additional Info : Peak(s) manually integrated VWD1 A, Wavelength=210 nm (20161205\\20161205 2016-12-05 15-57-19\\005-0301.D) 6.821mAU2001000-100-20002.557.51012.51517.5min ===================================================================== Area Percent Report ===================================================================== Sorted By : SignalMultiplier: : 1.0000Dilution: : 1.0000Use Multiplier & Dilution Factor with ISTDs Signal 1: VWD1 A, Wavelength=210 nm Peak RetTime Type Width Area Height Area # [min] [min] [mAU*s] [mAU] %----|-------|----|-------|----------|----------|--------| 1 6.821 MM 0.2137 3412.90210 266.17160 100.0000 Totals : 3412.90210 266.17160 ===================================================================== *** End of Report ***HPLC-10 2016-12-06 08:57:37 CWQ_497Page 1 of 1

因篇幅问题不能全部显示,请点此查看更多更全内容